{"id":4619,"date":"2019-11-15T16:12:29","date_gmt":"2019-11-15T16:12:29","guid":{"rendered":"https:\/\/c4n6.com\/site\/?p=4619"},"modified":"2019-12-30T16:19:46","modified_gmt":"2019-12-30T16:19:46","slug":"blocked-egress","status":"publish","type":"post","link":"https:\/\/c4n6.com\/site\/blocked-egress\/","title":{"rendered":"Blocked Egress"},"content":{"rendered":"<p>In this November edition of our HUD-REAC newsletter, I\u2019d like to discuss HUD\u2019s protocol on Blocked Egresses and how you can comply!<\/p>\n<p>&nbsp;<\/p>\n<p><strong><u>General Rules<\/u><\/strong><\/p>\n<ul>\n<li>Doors and doorways are <u>ALWAYS<\/u> considered primary egress\n<ul>\n<li>If a room has 2 doors and a window \u2013 the window can be blocked as long as both doors are accessible\/egressable<\/li>\n<\/ul>\n<\/li>\n<li>All rooms <u>up to<\/u> the 3<sup>rd<\/sup> floor \u2013 if the room is <strong><u>designed<\/u><\/strong> with 2 means of egress, both must be egressable.\n<ul>\n<li>What does this really mean?\n<ul>\n<li>A closet is typically <u>designed<\/u> with only 1 egress \u2013 the door. An inspector cannot require you to install a window to meet the 2 means of egress rule<\/li>\n<li>Some buildings have windows that are <u>designed<\/u> to open 6 inches or are leuvered, which makes them non-egressable windows \u2013 since they are not <u>designed<\/u> to be egressable, they are not required to be!<\/li>\n<\/ul>\n<\/li>\n<li>No items can be stored on an exterior fire escape.<\/li>\n<li><strong>Security Bars<\/strong>\n<ul>\n<li>When fixed security bars (with <u>no<\/u> quick release) are installed on the only 2<sup>nd<\/sup> means of egress from a room on the third floor or lower or on any floor where the window leads to a fire escape, a blocked egress <u>will be<\/u><\/li>\n<li>A hasp on security bars itself is <u>NOT<\/u> a deficiency, <strong>unless<\/strong> there is a locking mechanism (whether locked or unlocked) on the hasp or requires a tool to get the security bars open.<\/li>\n<li>The break-away for security bars <u>cannot<\/u> be blocked by a bed or other furniture<\/li>\n<\/ul>\n<\/li>\n<li><strong>Child Safety Window Guards<\/strong>\n<ul>\n<li>Normally found in apartments and public hallways to protect children 10 years and younger from falling to the outside.<\/li>\n<li>Typically lightweight metal construction and can be dislodged with a reasonable degree of force when necessary.<\/li>\n<li>Are NOT a blocked egress unless they are improperly installed or constructed.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<div id=\"attachment_4621\" style=\"width: 594px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4621\" src=\"https:\/\/c4n6.com\/site\/wp-content\/uploads\/2019\/12\/safety-guards.png\" alt=\"Approved Child Window Safety Guards\" width=\"584\" height=\"485\" class=\"size-full wp-image-4621\" srcset=\"https:\/\/c4n6.com\/site\/wp-content\/uploads\/2019\/12\/safety-guards.png 584w, https:\/\/c4n6.com\/site\/wp-content\/uploads\/2019\/12\/safety-guards-300x249.png 300w\" sizes=\"auto, (max-width: 584px) 100vw, 584px\" \/><p id=\"caption-attachment-4621\" class=\"wp-caption-text\">Approved Child Window Safety Guards<\/p><\/div>\n<li><strong>Windows<\/strong>\n<ul>\n<li>Inspectors are required to \u201cuse their professional judgment\u201d to determine if the level of effort required to open a window constitutes a deficiency for being inoperable and\/or a blocked egress.<\/li>\n<li>If the only window in a room has an Air Conditioner installed in it \u2013 <strong>whether secured or not<\/strong> \u2013 it is a blocked egress.\n<ol>\n<li>Floor A\/C units with the vent attached at the window with a slider kit are <u>absolutely acceptable<\/u> as long as the slider kit is installed correctly \u2013 no tape, glue, screws, etc!<\/li>\n<li>I have seen many successful installations using a weather strip to prevent insects and air gaps \u2013 no tape!<\/li>\n<li>I recommend installing a stick or thumb lock on the window if the tenant has the vent through the window for security. The inspector will remove the vent and test the primary lock but it\u2019s good to have the window secured since the tenants typically do not remove the vent when they leave their units.<\/li>\n<\/ol>\n<\/li>\n<li>If the window doesn\u2019t open or does not stay open by itself, it\u2019s a blocked egress.<\/li>\n<li>For Nursing Homes, Dementia, Behavioral Health Centers, etc \u2013 If the window is intentionally blocked for tenant safety <strong><u>AND<\/u><\/strong> meets State and Local Codes (is approved by the Fire Marshal) you will need to do the following:\n<ol>\n<li>Get a letter from the Fire Marshal on his\/her letterhead, signed, dated with his\/her license number approving the blockage.<\/li>\n<li>File a Pre-Database Adjustment (Pre-DBA) with HUD and request the Pre-DBA be <strong><u>permanently applied<\/u><\/strong> for all blocked egresses <strong><u>AND<\/u><\/strong> Level 3 Window Inoperable defects.<\/li>\n<\/ol>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>*Inspectors will still record the L3 Inoperable Window and EH&amp;S for Blocked Egress, but with the Pre-DBA in place \u2013 those scored items will be removed prior to report release!<\/p>\n<ul>\n<li>If a tool (screwdriver, pliers, etc.) is required to open a window that is considered a 2<sup>nd<\/sup> egress \u2013 it\u2019s blocked.<\/li>\n<li>When looking at a window that has a partial obstruction due to furniture, ask yourself 2 questions:\n<ol>\n<li>Can a bulky firefighter with all his\/her gear get in <u>quickly?<\/u><\/li>\n<li>Can a child\/elderly person get out <u>quickly?<\/u><\/li>\n<\/ol>\n<\/li>\n<\/ul>\n<p>Or you can go by Code:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-4622\" src=\"https:\/\/c4n6.com\/site\/wp-content\/uploads\/2019\/12\/code.png\" alt=\"\" width=\"959\" height=\"553\" srcset=\"https:\/\/c4n6.com\/site\/wp-content\/uploads\/2019\/12\/code.png 959w, https:\/\/c4n6.com\/site\/wp-content\/uploads\/2019\/12\/code-600x346.png 600w, https:\/\/c4n6.com\/site\/wp-content\/uploads\/2019\/12\/code-300x173.png 300w, https:\/\/c4n6.com\/site\/wp-content\/uploads\/2019\/12\/code-768x443.png 768w\" sizes=\"auto, (max-width: 959px) 100vw, 959px\" \/><\/p>\n<ul>\n<li><strong>Doors<\/strong>\n<ul>\n<li>Double-sided Keyed Deadbolts<\/li>\n<\/ul>\n<\/li>\n<li><strong>Permitted to be installed:<\/strong><\/li>\n<\/ul>\n<ol>\n<li>Common Area laundry rooms, shops and offices \u2013 as long as they are not in the direct path of egress for the units<\/li>\n<li>Unit mechanical closets<\/li>\n<li>Unit <u>exterior<\/u> sheds and\/or <u>exterior<\/u> storage closets<\/li>\n<\/ol>\n<ul>\n<li><strong>Not permitted<\/strong><\/li>\n<\/ul>\n<ol>\n<li>Any common area in the direct path of Unit egress (hallways, lobbies, stairways, etc)<\/li>\n<li><u>Any door<\/u> in the unit, including the security door. Exception: The mechanical closet or exterior shed\/closet (see above)<\/li>\n<\/ol>\n<ul>\n<li>If ANY door in the direct path of egress requires the use of a tool (key, screwdriver, combination, etc) to open it \u2013 it\u2019s blocked. For example, an inverted passage lock on a bathroom, bedroom, or closet door.<\/li>\n<li>Hasp locks (other than for security bars, mechanical closets or exterior sheds\/closets) are an <u>automatic blocked egress whether the padlock is present or not.<\/u><\/li>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/c4n6.com\/site\/wp-content\/uploads\/2019\/12\/padlock.png\" alt=\"\" width=\"367\" height=\"210\" class=\"aligncenter size-full wp-image-4620\" srcset=\"https:\/\/c4n6.com\/site\/wp-content\/uploads\/2019\/12\/padlock.png 367w, https:\/\/c4n6.com\/site\/wp-content\/uploads\/2019\/12\/padlock-300x172.png 300w\" sizes=\"auto, (max-width: 367px) 100vw, 367px\" \/><\/p>\n<li>Lastly, the inspector will consider the tenant population when evaluating obstructions in the path of egress. For instance, in a senior building where a unit has an excessive amount of disorganized belongings, an inspector would not expect the resident to be able to parkour their way to the door or window in the event of a fire.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In this November edition of our HUD-REAC newsletter, I\u2019d like to discuss HUD\u2019s protocol on Blocked Egresses and how you can comply! &nbsp; General Rules Doors and doorways are ALWAYS considered primary egress If a room has 2 doors and a window \u2013 the window can be blocked as long as both doors are accessible\/egressable [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[129],"tags":[],"class_list":["post-4619","post","type-post","status-publish","format-standard","hentry","category-hud-reac"],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/c4n6.com\/site\/wp-json\/wp\/v2\/posts\/4619","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/c4n6.com\/site\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/c4n6.com\/site\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/c4n6.com\/site\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/c4n6.com\/site\/wp-json\/wp\/v2\/comments?post=4619"}],"version-history":[{"count":1,"href":"https:\/\/c4n6.com\/site\/wp-json\/wp\/v2\/posts\/4619\/revisions"}],"predecessor-version":[{"id":4623,"href":"https:\/\/c4n6.com\/site\/wp-json\/wp\/v2\/posts\/4619\/revisions\/4623"}],"wp:attachment":[{"href":"https:\/\/c4n6.com\/site\/wp-json\/wp\/v2\/media?parent=4619"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/c4n6.com\/site\/wp-json\/wp\/v2\/categories?post=4619"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/c4n6.com\/site\/wp-json\/wp\/v2\/tags?post=4619"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}